Replace lower solenoid valve on Ecam 350.55
Service Technician at Brewive • 2026-04-14 • 3 min read
If no more coffee comes out, one of the solenoid valves may not be working. To check, you can use the test mode, which will allow you to hear the valves clicking quietly. If you don't hear a click, it is probably defective.
Note: The opening is shown on a different model; there are slight visual differences.
What you need
Difficulty: Moderate | Estimated time: 15-30 minutes
Tools
- T20 Torx Screwdriver Bit
Step-by-step repair guide
Step 1
⚠️ Caution: Unplug the power cord!
Remove all attachments such as water tank, pulp drawer, brew group.
Turn the machine with the back facing you.
Remove five Torx T20 security screws.
💡 Note: A small hurdle: These screws have a pin in the middle, so the screwdriver must have a hole.
Step 2
Lift out the back.
The following components are immediately visible:
grinder
pump
flowmeter
Step 1
Push the side panel back about 1.5 cm.
Lift off the panel.
The following compononents are exposed:
Heater
Expansion chamber
Gear drive
Steam valve
Step 1
💡 Note: The lower solenoid valve is located on the lower left side of the device.
Pull out the clip between the solenoid valve and the pressure relief valve.
Lift the pressure relief valve upwards.
There is a seal between them. It will probably get stuck in the pressure relief valve. Remove it and replace it with a new one.
Step 2
Pull the valve together with the rubber sleeve away from the machine toward you.
Note how the cables are connected and remove all the blade terminals.
Remove the clamps and take out the hoses.
There is a seal ring between them. It will probably remain stuck in the solenoid valve. Remove it and replace it with a new one.
Step 3
Remove the valve from the rubber housing.
There is a black angle fitting on the right side of the valve. Pull out the clip and remove the angle fitting. The clip is slightly larger then the others. There is also a seal between them, which you should replace later
💡 Note: You can try to open the valve, clean it, and make it work. If the valve coil has a resistance of about 2 kOhm, it may work again. But you will probably have to replace it.
⚠️ Caution: When installing a new valve, pay attention to the direction of flow; the flow points toward the black mark or is indicated by an arrow. If you install it incorrectly, the machine will not work.
Solenoid valve three-way bottom DeLonghi
Order this genuine spare part for your DeLonghi coffee machine. Fast delivery and expert support from Brewive.
SET Hose gasket for DeLonghi full-automatic coffee machines - 10x
Order this genuine spare part for your DeLonghi coffee machine. Fast delivery and expert support from Brewive.
DeLonghi Descaler ECODECALK 500ml
Order this genuine spare part for your DeLonghi coffee machine. Fast delivery and expert support from Brewive.
Conclusion
Follow the steps in reverse order to reassemble your device.